1 H05-333 Burner 24 NG 1 8 716 105 484 0
2 H05-352 Burner 28 NG 1 8 716 105 485 0
3 H05-337 Gas Valve NG 1 8 716 105 654 0
4 H05-338 Gas Valve LPG 1 8 716 105 650 0
5 E80-454 Air Pressure Switch 1 8 747 004 461 0
6 E94-710 E lectrode Spark 1 8 716 105 186 0
7 E01-612 E lectrode FlameSense 1 8 716 120 345 0
8 H05-408 Fan 1 8 717 105 652 0
9 173-015 Overheat Stat 1 8 716 142 303 0
10 375-696 Thermistor Sensor 1 8 716 142 302 0
11 E88-181 Flow Sensor 1 8 716 146 164 0
12 H05-261 Heat Exchanger 24 kW 1 8 716 105 482 0
13 H05-264 Heat Exchanger 28 kW 1 8 716 105 483 0
14 H05-247 Insulation Set 24 kW 1 8 716 105 936 0
15 H05-248 Insulation Set 28 kW 1 8 716 105 937 0
16 E88-176 Pressure Gauge 1 8 716 142 398 0
17 375-699 Pressure Relief Valve 1 8 716 142 404 0
18 H05-366 Pump 1 8 716 105 656 0
19 H05-206 Expansion Vessel 1 8 716 105 545 0
20 H05-452 Control Board 1 8 748 300 484 0
21 H05-229 Silicone Sponge 24/28kW sides 1 8 716 105 766 0
22 H05-231 Silicone Sponge 24kW top/bottom 1 8 716 105 767 0
23 H05-239 Silicone Sponge 28kW top/bottom 1 8 716 105 768 0
24 E88-183 Transformer 1 8 747 210 294 0
25 E88-184 Flow Regulator 24kW White 1 8 716 141 255 0
26 E88-184 Flow Regulator 28kW Blue 1 8 716 141 253 0
27 H05-403 Auto Air Vent 1 8 716 106 142 0
A001 Charging Link Assembly 1 7 716 192 281
A002 Installer Pre-Filling Kit 1 7 716 192 282
A004 Gas Conversion Kit NG to LPG 24kW 1 8 716 105 967
A005 Gas Conversion Kit NG to LPG 28kW 1 7 716 192 290
A006 Simplefit Telescopic Flue Kit 1 7 716 191 068
A007 Vertical Flue Kit 1 7 716 191 079
A008 90° Flue Elbow - F106E90 1 7 716 191 013
A009 45° Flue Elbow (Pair) - F 106E45 2 7 716 191 014
A010 Vertical Flue Adaptor Kit 1 7 716 191 016
A011 Security Kit 1 7 716 192 246
A012 Mechanical Programmer 1 7 716 192 027
A013 Digital Programmer 1 7 716 192 028
A014 Digistat 1 7 716 192 030
Key G.C. No. Part Qty WHS
No. Part No.
31
17. Short Parts List
Accessories and Kits
11.7 Install the Boiler
Check that the gas and water valves are closed. Refer to Fig 13.
Fit the fibre washers, in the hardware pack, to the service valves
on the manifold.
Remove the two fixing screws.
Lift the appliance to the wall, engage in the top support and
lower onto the manifold assembly. Tighten the gas and water
connections.
Unscrew the facia fixing screws. Refer to Fig 18.
Unhook the panel and lower it into the bottom support lugs. Do
not strain the support strap. Refer to Fig. 18 and 41.
Fix the boiler at the right and left to the mounting frame using
the two lower fixing screws provided. Refer to Fig. 13 and 16.
Remove the protective cap from the flexible hose.
Check that the O-ring is in good condition.
Connect the hose to the system connection point-
SECURE IN POSITION WITH SPRING CLIP.
Refer to Figs 12 & 17.
Fit a discharge pipe to the relief valve leading it
away from any electrics or where it might be a hazard. The pipe
must not be less than 15mm in diameter and must run
continuously downward outside the appliance. Refer to Fig. 17.
14
65
65
65
65
CH
Flow
DHW
Flow
Gas
DHW
Cold
Inlet
CH
Return
Fibre
Washer
Fig. 13 . Manifold assembly
All dimensions in mm
Fig. 14 . Facia cover
1
1. Cabinet
2. Control
3. Facia cover
4. Facia cover clips (4)
5. Cabinet fixing screws (2)
2
3
4
Fig. 15 . Appliance location
1. Casing location bracket
2. Appliance location bracket
3. Wall mounting frame
4. Pipe channel
2
1
4
5
*
*
Filling loop not shown
Fig. 16 . Appliance fixing
3
1
2
1. Appliance fixing bracket
2. Fixing screw
!
IMPORTANT
Lower fixing
screws (2)