Greenstar Highflow CDi combi boiler
vertical fluing options
Greenstar Highflow CDi combis offer a choice of 2 different
sized vertical RSF systems, 100mm diameter and 125mm
diameter. Both systems have different maximum lengths.
Options 1 to 3 detail the permissible lengths.
Vertical RSF flue
Vertical balanced flue kit
Comprises:
1 x flue terminal assembly
1 x weather sealing collar
1 x fire stop spacer
1 x vertical flue adaptor
1 x wall bracket
1 x flue adaptor
Part No. 7 716 191 156 (100mm dia.)
Part No. 7 716 191 158 (125mm dia.)
Accessories
Flue diameter 100mm 125mm
Flue terminal assembly diameter 120mm 135mm
Maximum flue length
(inc. terminal)
6,400mm 15,000mm
Flue terminal assembly length 1,140mm 1,365mm
Option 1
Vertical balanced flue assembly
300mm
500mm
Pitched
roof
Flat roof
Maximum
Components required
length (m)
60/100 6.4 1 up to 6
80/125 15 1 up to 14
Option 2
Vertical balanced flue using two 45º bends
Min.
120mm
Maximum
Components required
length (m)
60/100 4.9 1 up to 5 2
80/125 13 1 up to 12 2
Option 3
Vertical balanced flue using two 90º bends
Min.
120mm
Maximum
Components required
length (m)
60/100 3.4 1 up to 3 2
80/125 11 1 up to 10 2
Components Part no. Description
7 716 191 156 60/100 Vertical 1,140mm kit
7 716 191 083 60/100 1m extension
7 716 191 084 60/100 90º bend
7 716 191 085 60/100 45º bend
7 716 191 133 60/100 Short flue extension
7 716 191 158 80/125 Vertical 1,365mm kit
7 719 001 892 80/125 1m extension
7 719 001 891 80/125 90º bend
7 719 001 899 80/125 45º bend