CONTROLS
Greenstar i System Compact – 6 720 807 727 (2013/05)
3.1.9 TURNING THE CENTRAL HEATING OFF DURING THE SUMMER
Turn your programmer/timer to the off position.
Please refer to the programmer/timer manufacturer's instructions.
3.1.10 BOILER FROST PROTECTION
If you are leaving your property unoccupied during cold weather, please leave your programmer on constant and your room
thermostat set to 15°C.
If the temperature within the boiler falls below 8°C the pump will run to circulate water and prevent the system freezing.
If the temperature does not rise to 9°C within 30 minutes of the pump operating, the boiler will fire up to provide heat to bring
the temperature up.
If the temperature within the boiler falls below 5°C the boiler will fire immediately, bringing the boiler temperature up to 1C to
avoid the possibility of the system freezing.
This process will be repeated until such time that the boiler temperature does not drop below 5°C.
3.1.11 TURN OFF THE OPERATION/FAULT DIAGNOSTIC LIGHT (BLUE)
Your new Greenstar iSystem Compact boiler is designed to use as little electricity as possible during operation and in stand-by
mode. To further enhance your energy saving during stand-by, you may choose to deactivate the Operation/fault diagnostic light.
The light will still flash to alert you to a possible fault, but will stay off when the boiler is in stand-by mode. Please ask your installer
to activate this feature.
NOTICE: The boiler must be switched on with a gas supply in order for the built -in auto frost protection to work as
described.