17
Technical data – advanced intelligent controls
Compatibility
Gas-fired boilers Oil-fired boilers
COMBI
SYSTEM
^
REGULAR*
COMBI SYSTEM REGULAR
CDi Classic
2
CDi Compact
Si Compact
Greenstar i
Highflow CDi
CDi Classic
System
27i System and
30i System
9i – 24i System
27Ri and 30Ri
Heatslave II
Heatslave II
External
Danesmoor
System
Danesmoor
Intelligent controls Part no.
FR10 intelligent
room thermostat
7 716 192 065
D
1
DD
2
DD D DD
3
FR110 programmable
room thermostat
7 716 192 066
D
1
DD
2
DDD
1
DD
2
FW100 weather
compensation controller
7 716 192 067
D
1
DD
2
DDD
1
DD
2
ISM1 intelligent
solar module
7 716 192 068
D
1
DD
2
Outdoor weather sensor 7 716 192 764
D D DD
*With optional wiring centre (see page 23). ^With optional integral diverter valve.
1
Manufactured after 16th January 2007 with software version CF12.10 onwards.
2
Manufactured after February 2011.
3
Must be used with an external propriety 230V timer.
Correct at time of printing. For the latest list of compatible boilers see the Worcester website.
17
Controller model FR10 FR110 FW100 ISM1
Height
85mm 119mm 119mm 110mm
Width
100mm 134mm 134mm 156mm
Depth
35mm 35mm 35mm 55mm
Rated voltage
EMS-BUS
10 – 24V DC 10 – 24V DC 10 – 24V DC 10 – 24V DC
Rated voltage
–––230V AC
Rated current
≤ 3.5 mA
6 mA
(exc. illumination)
6 mA
(exc. illumination)
4 A
Controller output
2-wire BUS 2-wire BUS 2-wire BUS 2-wire BUS
Maximum output
per connection
–––120W
Control range
5 – 30ºC
in steps of 0.5ºC
5 – 30ºC
in steps of 0.5ºC
5 – 30ºC
in steps of 0.5ºC
–
Permissible ambient
temperature
0 – +50ºC 0 – +50ºC 0 – +75ºC 0 – +50ºC
Protection level
IP20 IP20
IPX2D (fascia
mounted) IP20
(wall mounted)
IP44
Controller position
Wall mounted Wall mounted
Fascia mounted/
wall mounted
Wall mounted
ErP class with compatible
Greenstar gas-fired boilers
V V VI –
System efficiency benefit with
Greenstar gas-fired boilers
+3% +3% +4%* –
ErP class with compatible
Greenstar oil-fired boilers
I –––
System efficiency benefit with
Greenstar oil-fired boilers
+1%–––
*+4% when installed as a room sensor. When installed in the fascia of the boiler it becomes a +2% control (Class II)